Thin Profile Eco Range
Technical Data
Life Expectancy of >20,000 cycles (tested at 30 times per minute)
Permissible Axial Spindle Load: 50 N (5 Sec. maximum)
Permissible Torque at End Stop: 35 N.cm
Rotation angle: 300° ±5°
Detents (stop positions) Available: Centre, 11, 21
Operating Torque: 0.4 – 2.0 N.cm (Initial Torque may be higher)
Rotational torque of spindle can be made high or low
Cylindrical, Flatted and Splined Spindles available
Insulation Resistance: >= 4 Gohms
Insulation (Breakdown) Voltage: 2,500 V AC (except BR model)
Rated Resistance: E3 Series (Optional: E6 Series)
Linear Law: 1K – 1M
Non linear Law: 4K7 – 470K